Display: Shot

A shot in progress and its result: elapsed time as the reading, phase bars beneath it, pressure and weight as second-rank values, STOP in ink.

HTML
<div class="bm-stage">
  <figure class="bm-fig"><div data-face='{"s": "shot", "phase": "PREINFUSE", "time": "0:04", "tempF": 0.58, "targetF": 0.58, "pressureF": 0.14, "pTargetF": 0.19, "phases": [[1, 0.6], [1.5, 0], [2.5, 0]], "a": ["2.2", "BAR"], "b": ["0.8", "/ 36 G"]}'></div><figcaption>Preinfusion</figcaption></figure>
  <figure class="bm-fig"><div data-face='{"s": "shot", "phase": "RAMP TO 9 BAR", "time": "0:15", "tempF": 0.58, "targetF": 0.58, "pressureF": 0.56, "pTargetF": 0.5625, "phases": [[1, 1], [1.5, 1], [2.5, 0.35]], "a": ["9.0", "BAR"], "b": ["21.7", "/ 36 G"]}'></div><figcaption>Pulling, by weight</figcaption></figure>
  <figure class="bm-fig"><div data-face='{"s": "shot", "phase": "SHOT COMPLETE", "time": "0:29", "tempF": 0.58, "targetF": 0.58, "pressureF": 0.02, "pTargetF": -1, "phases": [[1, 1], [1.5, 1], [2.5, 1]], "a": ["36.4", "GRAMS"], "b": ["1:2.0", "RATIO"], "done": true}'></div><figcaption>Finished</figcaption></figure>
</div>
  • The ring is the same split ring as Brew, so nothing on the rim redraws when the shot starts. The pressure notch follows the running phase's target.
  • The label names the phase. Phase bars show one bar per phase, as wide as its planned duration, filling as it runs.
  • Pressure appears as a number only here. With a scale the second value is weight over its target; without one it is the boiler temperature.
  • If the boiler strays more than 3° from target, the label says so in heat-text (TEMPERATURE 88°) until it recovers.
  • STOP is ink, not cobalt: cobalt starts things.
  • On completion keep the layout: the label becomes SHOT COMPLETE, the values become yield and ratio, the pill becomes DONE in primary, and the pressure ticks walk down.

Content

  • The word is always phase, on the display as on the web. The label is the phase's own name in capitals, at most 20 characters: RAMP TO 9 BAR, PREINFUSE.
  • Elapsed time is m:ss (0:15); the final time on completion stays in the same format.
  • Second-rank values carry their unit as the label under them: 9.0 over BAR, 21.7 over G / 36.
  • At most five phase bars fit the 220 px row. With more, draw the running phase and its two neighbours.

Touch

STOP is the only target while a shot runs: 168 by 64 px, and nothing else on the screen responds, so a wet hand cannot change a setting mid-shot. The handle is hidden. STOP acts on touch down, not on release.

Provide: elapsed time, phase name and target, the phases with their durations and progress, pressure, weight and target weight.