Number field
A typed number with its unit inside the field: dose, yield, a phase's duration, a pressure target.
HTML
<div class="bm-stage">
<section class="bm-tile" style="width:366px">
<div class="bm-grid2">
<label class="bm-field"><span class="bm-field__label">Dose</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="decimal" value="18.0" aria-describedby="u1"><span class="bm-input__unit" id="u1" aria-label="grams">g</span></span></label>
<label class="bm-field"><span class="bm-field__label">Yield</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="decimal" value="36.0" aria-describedby="u2"><span class="bm-input__unit" id="u2" aria-label="grams">g</span></span></label>
</div>
<label class="bm-field"><span class="bm-field__label">Target temperature</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="numeric" value="93" aria-describedby="u3 h3"><span class="bm-input__unit" id="u3" aria-label="degrees Celsius">°C</span></span><p class="bm-help" id="h3">80 to 100 °C.</p></label>
</section>
<section class="bm-tile" style="width:366px">
<label class="bm-field"><span class="bm-field__label">Pressure</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="decimal" value="14.0" aria-invalid="true" aria-describedby="u4 e4"><span class="bm-input__unit" id="u4" aria-label="bar">bar</span></span><span class="bm-field__msg bm-field__msg--error" id="e4"><span data-icon="circle-alert" data-size="14"></span>Enter 0.0 to 12.0 bar.</span></label>
<div class="bm-grid2">
<label class="bm-field"><span class="bm-field__label">Flow limit</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="decimal" value="2.5" aria-describedby="u5"><span class="bm-input__unit" id="u5" aria-label="millilitres a second">ml/s</span></span></label>
<label class="bm-field"><span class="bm-field__label">Standby after</span><span class="bm-inputwrap"><input class="bm-input bm-input--num" inputmode="numeric" value="30" aria-describedby="u6"><span class="bm-input__unit" id="u6" aria-label="minutes">min</span></span></label>
</div>
</section>
</div>- Use it in the profile editor, where a value is typed once. On the dashboard, a value nudged in small steps is a Stepper.
- The unit is part of the field, not of the label: "Dose" with
ginside, never "Dose (g)".
Anatomy
.bm-inputwrap holding input.bm-input.bm-input--num and .bm-input__unit. The number is right-aligned in body with tabular figures and ends space-12 from the right edge; the unit sits in that space in unit, ink-muted, UPPERCASE. Use type="text" with inputmode="decimal": it gives the numeric keyboard without the spinner arrows and the scroll-wheel changes of type="number".
States
The Field's states. An out-of-range value is an error when the field loses focus: danger border, circle-alert, and a sentence that states the range.
Content
| Quantity | Unit shown | Decimals | Typical range |
|---|---|---|---|
| Temperature | °C | 0 | 80 to 100 |
| Pressure | BAR | 1 | 0.0 to 12.0 |
| Dose, yield | G | 1 | 0.0 to 100.0 |
| Flow | ML/S | 1 | 0.0 to 10.0 |
| Duration | S | 0 or 1 | 0 to 120 |
| Standby after | MIN | 0 | 0 to 240 |
- Accept a comma or a point as the decimal mark and show the point. Round to the decimals in the table when the field loses focus; never while typing.
- State the range in the help line when it is not obvious ("80 to 100 °C") and repeat it in the error.
- Empty is allowed only where the help says what empty means.
Keyboard and screen reader
- The visible label names the field. Link the unit into the name with
aria-describedbyon the unit's id, so it reads "Dose, 18.0, grams": give the unit anaria-labelwith the word ("grams") since "G" alone is read as a letter. - Up and Down change the value by one step (0.1 or 1), Shift with them by ten. Do not trap the scroll wheel.